Error Description Possible causes Troubleshooting
code
5804 Free Contours:
Wrong checksum
-
NV-SRAM faulty
-
Failure
-Check via Multitest,
check the control
-Switch the sewing machine off
and on again
Data will be reset to factory setting.
5808 Error free seam
contour
Cannot determine the
stitch number
Internal error
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
5809 Free contours:
Max. number of
contour parts
Max. number of contour
parts (intermediate cut)
exceeded
Delete some intermediate cut in the
free contours
5810 Free contours:
Min. number of stitches
per contour part
Cannot keep the min. number
of stitches per contour part
Move some intermediate cut in the
free contours
5900 Error sequences -
Invalid sequence
number
Internal error
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
6151
-
6154
Error input / output Internal error
· Switch machine off and on again
6351
-
6354
Error I²C Control faulty
Replace control
Software update
Contact the DA-Service staff
6551
-
6554
6651
-
6653
6751
-
6761
6952
Error
Machine head
position /
AD-Converter /
Processorerror/
Error step motor
driver
Internal error
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
7451
7453
7454
Communication Test
interface
Internal error
Switch machine off and on again
7452
7455
Communication
test interface
· Transmission failure
· Cable of test interface faulty
· Internal error
-Switch off the source of
interference
-Replace cable
- Switch machine off and on again
7551
-
7555
7558
7559
Communication
control panel interface
Internal error
-Switch off the source of
interference
-Replace cable
- Switch machine off and on again
7556
7557
Communication
control panel interface
· Transmission failure
· Cable of control panel
interface faulty
-Switch off the source of
interference
-Replace cable
- Switch machine off and on again
7700 Protocol: Max number
of repetition
· Transmission failure
· Cable of test interface faulty
-Switch off the source of
interference
-Replace cable