Input test
With this test function the input element to be tested is selected.
ATTENTION !
The input elements have been carefully adjusted in the factory.
Adjusting and correcting must only be done by trained service staff.
–
Start the test function with the “OK”key.
–
Select desired input element with the keys “ñ”or“ò”.
The The switching status of the input element is indicated.
input test
input
–
Press function key “ESC” for leaving the test function.
The menu Multitest is indicated.
Input element Function
S 1 Pedal 1
S 2 Pedal 2
S 3 Pedal 3
S 4 Pedal 4
S 5 Hand switch key 1, if the option is activated
S 6 Hand switch key 2, if the option is activated
S 7 Depending on the activated option and the input configuration
S 8 Query clamping foot
N-Ref. Sewing motor reference switch
X-Ref. X-reference switch
Y-Ref. Y-reference switch
The recent configuration of the inputs is indicated in the submenu
“Input configuration” of the menu Configuration.