Seitenansicht 44
Submenu Configuration
hand switch:off
laser light: off
opt. sign.
assignment input
assignment output
Hand switch
Activating of optional hand switches. When the option is switched on, a
menu item in order to select the operation mode will appear in the
menu “User configuration”.
Input:ON/OFF
Laser lights
Activating the 3 optional laser lights.
Input:ON/OFF
Optical signalling
Via this submenu an indication of error and event messages and of the
message “hook thread is zero” can be configurated and activated via
two 24V-outputs.
Optical signalling
Activating of the indication. Beforehand outputs 1 and 2
must be configurated, otherwise this menu item cannot be
selected.
Input: ON/OFF
Output 1
Selection of the output for error and event messages.
Input: 1 ...8 (if 24V-outputs are vacant)
Output 2
Selection of the output for the message “hook thread is
zero”
Input: 1 ...8 (if 24V-outputs are vacant)
Assignment of the inputs
This menu item gives on overall view of the assignment of the inputs
with (optional) units.
Assignment of the 24V-outputs
This menu item gives an overall view of the assignment of the
24V-outputs with optional units.