6.2 Plug connections at the multiple pin strip (15 fold)
Connect the plug connectors of the buttonhole automat,
the set value initiator and the control panel as follows:
REF-signals
Light barrier plug /sensor
on plug connector 4
Note: 8-pole plug is coded.
Plug PWM (optional with the electronic thread
tensioner)
Magnetic plugs on plug connector 8
Note: 8-pole plug is coded.
Encoder plug sewing motor
Encoder plug signal sewing motor
on plug connector 5
Control panel plug
Control panel plug
on plug connector 6
Plug I/O 1-8
Operating device plug (pedal switch)
via adapter 9 on plug connector 7
Test-Interface 10
Dongle
6.3 Potential compensation
Screw the potential compensation cable onto the
control panel.
17
2
8
10
9
4
5
6