7. Pneumatic connection
7.1 Connecting the maintenance unit
–
Connect the air hose 6 to the coupling.
–
Connect the hose nozzle 7 with an air hose onto its air supply
connection.
A pneumatic connection kit for the connection onto the existing air
pressure network is available under order number: 0797 003031.
–
Connect the cable 9 to the pneumatic switch 8.
CAUTION!
The operating pressure is 6 bar. Check the maintenance unit to see
whether 6 bar are indicated! If necessary, adjust the pressure on the
maintenance unit to 6 bar.
7.2 Connecting the waste container
–
Connect the air hose 8 (the thinner one of the two black air hoses)
to the waste container.
–
Connect the hose 9 to the waste container. Hose 9 is used to
exhaust cutting waste.